ZHEJIANG WEIHAO ELECTRONIC CO.,LTD
Products
Contact Us
  • Contact Person : Mr. Xiaoyan yu
  • Company Name : ZHEJIANG WEIHAO ELECTRONIC CO.,LTD
  • Tel : 86-577-61777088
  • Fax : 86-577-61777072
  • Address : zhejiang,yueqing,No.231,WeiLiu Road
  • Country/Region : China
  • Zip : 325600

S-201

S-201
Product Detailed
Related Categories:Agricultural Product Stock
Features:High efficiency, high reliabilitySwitch input voltage range choice100% full load and machine testProtection characteristics: short circuit/overload/pressure/thermalAir coolingWorking frequency 25 KHz2 years warrantySize: 215*115*50mm(L*W*H)modelS-201-12S-201-13.5S-201-15S-201-24S-201-27S-201-48outputDc output voltage12V13.5V15V24V27V48VOutput voltage tolerance±1%±1%±1%±1%±1%±1%Rated output current16.5A14.7A13A8.3A7.4A4.2AOutput current range0-16.5A0-14.7A0-13A0-8.3A0-7.4A0-4.2AOutput power198W198.45W198W199.2W199.8W201.6WRipple and the noise150mVp-p150mVp-p150mVp-p150mVp-p200mVp-p240mVp-pDc voltage adjustable scope-16%,+10%-12%,+11%-10%,+20%-16%,+10%-4%,+18%-15%,+17%Start, rise, keep time200ms,100ms,20ms Loaded withinputInput voltage range90~132 VAC/180~264VAC By switch 47~63 Hz 254~370VDCExchange input current4.5A/115VAC 2.5A/230VACefficiency76%79%78%82%82%83%Impulse current50A/115V 50A/230VLeakage current<3.5 mA/240VACProtection characteristicsOverload protection115%~135%Protection way: current limiting, automatic recoveryOvervoltage protection115%~135%Protection way: voltage limitation, automatic recoveryHigh temperature protectionRTH3 acuity 90 ℃, the temperature drop, cut off output automatically after recoveryenvironmentWorking temperature, humidity-10℃~+50℃;20%~90 %RHKeep temperature, humidity-20℃~+85℃;10%~95 %RHVibrate resistance10~500Hz,2G 10min./ 1 cycle time, 60 minutes, the axissecurityCompression sexInput/output: 1.5 KVAC input and between to KVAC output and the earth: 1.5:0.5 KVACInsulation resistanceBetween the input and output, the input and output, and ground: 100M Ohms/500VDCstandardSafety standardsmeet UL1950EMC standardDrsign refer to FCC Part15 J Conduction Class Aotherweight0.9Kgpackaging20pcs/18Kgnote1.All the parameters in has not specified, all is in 230 VAC voltage input, rated load and 25 ℃ conditions measuring income value.2.Ripple and noise voltage is in 20 MHz bandwidth oscilloscope take 12 inches twisted pair end with 0.1 mu and 47 u when capacitance measurement.3.Tolerance is voltage setting error, the voltage adjustment rate and adjust the sum total of the current rate.4.Specific output current see output drop forehead curve.


Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.